| For Active Uses – Early Stage Fire Only |
The ELIDE FIRE® Ball is designed to suppress incipient fires — typically within the first 1–5 minutes of ignition, before flames fully develop or spread. It is intended for initial fire suppression and not for ongoing or large-scale fires. Portable extinguishing tools (such as handheld fire extinguishers, aerosol sprays, or other small suppression devices) also follow this same standard of use for early-stage fires. Using the ELIDE FIRE® Ball beyond this stage may help slow flame spread but may not fully extinguish a developed fire. |
| Do not install the device in direct contact with materials that generate heat. |
Avoid placing the ELIDE FIRE® Ball in direct contact with materials surface or equipment that generate heat to prevent melting or malfunction. |
| Maintain at least 5 cm clearance around the ELIDE FIRE® Ball. |
Ensure at least 5 cm of empty space around the ball to prevent obstruction and allow for proper activation. |
| Do not use the device as a replacement for sprinkler or foam systems. |
The ELIDE FIRE® Ball is a supplementary tool and should not replace sprinkler systems or foam systems, especially in large or wide areas. |
| Do not throw or drop from a height exceeding 2.5 meters. |
Excessive height can cause the product to break, leading to damage and failure to function properly. |
| Do not use for throwing on Class B fires (flammable liquids and gases). |
Avoid tossing or throwing the device at fires involving flammable liquids, as it may spread the flames instead of extinguishing them. |
| Install at appropriate height for Class B fires. |
For fires involving flammable liquids or gases, install the device 60–80 cm above the risk point to minimize the risk of liquid displacement caused by activation pressure. |
| Avoid installation in open or exposed areas. |
Do not install the ELIDE FIRE® Ball in areas exposed to rain, water, or open environments with high winds, as these conditions may affect its performance. |
| Install with the arrow pointing upward. |
During installation, ensure the yellow arrow on the ELIDE FIRE® Ball is pointing upward to allow proper functionality. |
| Consider fire dynamics (flow path). |
Install the ELIDE FIRE® Ball above potential fire sources, taking into account that fires typically spread upward with airflow. Avoid placing it too low where it may not activate effectively. |
| Designed for initial fire suppression. |
The ELIDE FIRE® Ball is designed to suppress fires during the first 4 minutes of ignition. For fires beyond this duration, the device may slow the spread but may not fully extinguish the fire. |
| Use multiple ELIDE FIRE® Balls for larger fires. |
For fire volumes exceeding 2.5 m³, use multiple units at the same time to ensure comprehensive suppression. A single unit may not be sufficient for larger fires. |
| Avoid underinstallation. |
Ensure the number of ELIDE FIRE® Balls installed matches the size and risk level of the space. Do not install fewer units than needed for the area or volume. |
| Install safely in electrical cabinets. |
Choose a model that is suitable for the volume of the electrical cabinet. Avoid using a model that is too small for the enclosure. |
| Supplemental tool only. |
The ELIDE FIRE® Ball is an additional safety tool and should not replace traditional fire extinguishers or full-scale fire suppression systems. |
| Safety compliance for testing. |
Testing of ELIDE FIRE® products must be conducted only by qualified professionals in a controlled setting. Improper testing or use by individuals without fire safety expertise is strictly prohibited, as it may lead to unsafe conditions. |
| Prohibited modifications and dismantling. |
Any form of modification, dismantling, or reverse engineering of ELIDE FIRE® products is strictly forbidden. |
| Do not trash. |
Do not dispose of in regular waste. Follow proper disposal guidelines for fire suppression equipment. |